5 [settings] [jog mode, 6 [settings] [co parameters, Settings] [jog mode – Festo Контроллеры двигателя SFC-LAC User Manual

Page 99: Settings] [co parameters

Advertising
background image

4. The control panel (only type SFC−LACI−...−H2−...)

4−17

Festo GDCP−SFC−LACI−CO−EN en 0812NH

4.5.5

[Settings] [Jog Mode]

You can use the arrow keys to move the drive continuously
(also possible without previous homing run). The software
end positions have no effect here.

4.5.6

[Settings] [CO parameters]

Setting the fieldbus parameters

[CO parameter]

Param.

Description

[CAN node ID]

1 ... 127
(1 ...7fh)

Fieldbus address of the SFC−LACI.
Representation: 1 dec, 1 hex"...127 dec, 7f hex"

[CAN baud rate]

1000 kBd,
800 kBd,
500 kBd,
250 kBd,
125 kBd,
100 kBd,
50 kBd,
20 kBd,
10 kBd

Fieldbus baud rate as per settings on master.

[CAN profiles]

DS402,
FHPP

Profile with which communication between the CAN master and
the SFC−LACI is handled:
Ĉ DS 402: Control takes place as per DS 402.
Ĉ FHPP: Control takes place as per Festo Handling and Positioning

Profile.

[CAN Volt.Supply]

internal,
external

Power supply to the fieldbus node can take place internally," i.e.
via the logic voltage supply of the SFC−LACI, or externally" via the
fieldbus (via optocoupler electrically isolated from the logic voltĆ
age of the SFC−LACI), see section 3.6.

Tab. 4/6: Menu [Settings] [CAN parameter]

The settings in the menu [CAN parameter] are saved directly
and permanently (including in the event of a power failure) in
the EEPROM after confirmation with OK <Enter>.

Advertising