Electronic type plate – Festo Контроллеры двигателя SFC-LAC User Manual
Page 312
B. Parametrising as per FHPP−FPC
B−84
Festo GDCP−SFC−LACI−CO−EN en 0812NH
Electronic type plate
Motor type
PNU
1030
ć
uint16
r
Description
Classification of the motor. Fixed: 0x0000.
CI / DS402
6402h
00h
uint16
r
Maximum current
PNU
1034
ć
uint16
rw
Description
Maximum motor current in per mill of rated current (PNU 1035).
Note: The current limitation also limits the max. possible speed (or force).
Higher setpoint speeds may not therefore be reached, or the drive stops.
During homing: At greatly reduced values combined with high travelling
resistance, there is a danger that the drive will come to a standstill and the
SFC−LACI will wrongly recognize a stop.
CI / DS402
6073h
00h
uint16
rw
Rated motor current
PNU
1035
ć
uint32
rw
Description
Nominal current of the motor in [mA]. The value is fixed.
CI / DS402
6075h
00h
uint32
rw
Rated motor torque/force
PNU
1036
ć
uint32
rw
Description
Nominal force of the linear motor in [mN]. The value is fixed.
CI / DS402
6076h
00h
uint32
rw