B. Parametrising as per FHPP−FPC

B−84

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Electronic type plate

Motor type

PNU

1030

ć

uint16

r

Description

Classification of the motor. Fixed: 0x0000.

CI / DS402

6402h

00h

uint16

r

Maximum current

PNU

1034

ć

uint16

rw

Description

Maximum motor current in per mill of rated current (PNU 1035).
Note: The current limitation also limits the max. possible speed (or force).
Higher setpoint speeds may not therefore be reached, or the drive stops.
During homing: At greatly reduced values combined with high travelling
resistance, there is a danger that the drive will come to a standstill and the
SFC−LACI will wrongly recognize a stop.

CI / DS402

6073h

00h

uint16

rw

Rated motor current

PNU

1035

ć

uint32

rw

Description

Nominal current of the motor in [mA]. The value is fixed.

CI / DS402

6075h

00h

uint32

rw

Rated motor torque/force

PNU

1036

ć

uint32

rw

Description

Nominal force of the linear motor in [mN]. The value is fixed.

CI / DS402

6076h

00h

uint32

rw