1 diagnostics options, Diagnostics options – Festo Контроллеры двигателя SFC-LAC User Manual
Page 203
![background image](/manuals/464473/203/background.png)
6. Diagnostics and error display
6−3
Festo GDCP−SFC−LACI−CO−EN en 0812NH
6.1
Diagnostics options
Overview organised according to the type of the diagnostic
information:
Type of diagnostic
information
Access via ...
see ...
General status display
LEDs on the SFC−LAC
Section 6.2
FCT: virtual LEDs in the Device status" window
Help for
plug−in
FHPP status bytes SCON and SPOS
Section 5.5.2
The current error message in plain
text
SFC−LAC control panel (type ...−H2 only)
Section 6.3
text
FCT: Text field in the Device status" window
Help for
plug−in
Diagnostic memory: the last
16 messages
FCT: in the Diagnosis" window (with existing
device connection)
Help for
plug−in
FPC: The second 8 bytes of the cyclic field bus
communication can also transfer the contents
of the diagnostic memory.
Diagnosis via CANopen
Emergency messages
Node guarding
DS402 status word
Section 6.5
Parameterising
Control panel: in the [Diagnosis] menu
Section 4.3
FCT
Help for
plug−in
Tab. 6/1: Diagnostic information according to type