C. Object directory DS402 and CI

C−26

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Transmit PDO communication parameter

DS402

1800h,
1801h

01h...05h

Record

rw

Description

Communication parameters of PDOs 1 and 2 which the device can transmit:
Ĉ PDO 1:

Object 1800h

Ĉ PDO 2:

Object 1801h

COB ID for PDO 1800h,

1801h

01h

uint32

COB ID used by the PDO.
Ĉ PDO 1:

Default: 0x180 + Node ID

Ĉ PDO 2:

Default: 0x280 + Node ID

Transmission type 1800h,

1801h

02h

uint8

Transmission type
Default: 255 (0xFF) ć Event−triggered asynchronous transmission
Value range: 0 ... 255 (0x00 ... 0xFF)

Inhibit time 1800h,

1801h

03h

uint16

Inhibit time. Default: 0

(Reserved) 1800h,

1801h

04h

ć

Reserved, must not be implemented (access attempts are answered with abort
code).

Event timer

1800h,
1801h

05h

uint16

Event counter in [ms]. Default: 0 (0x0000)