Product−specific terms and abbreviations

Term / abbreviation

Meaning

Acknowledge

Confirm, reply message, e.g. Acknowledge START."
Acknowledge a fault." The user confirms that he has noted the fault.
The device then leaves the fault status (if the fault still exists, it will be
displayed again).

Applied load
(additional load)

The mass of a workpiece. Applies only to a single positioning record,
see Fig. 0/1.

AZ (= axis zero point)

Axis zero point. See section 1.1.5.

EMC

Electromagnetic compatibility

FCT
(= Festo Configuration
Tool)

Software with uniform project and data management for all supported
device types. The special requirements of a device type are supported
with the necessary descriptions and dialogues by means of plug−ins.

FHPP

Festo Handling and Positioning Profile:" Uniform fieldbus data profile
for positioning controllers from Festo. See 1.2.3.

FHPP standard

FHPP sequence control. See 1.2.3.

FPC

Festo Parameter Channel" for parameter access. See section 1.2.3.

HALT

With a HALT signal a running positioning movement is interrupted and
the drive stops. The positioning record remains active, i.e.Ăwith a new
START signal the record will be continued. Compare STOP.

HMI

Human Machine Interface" refers to the control panel on the variant
SFC−LAC−...−H2. [HMI = on] means that parameterisation and operation
can begin using the control panel or FCT. The control interface is then
deactivated.

Homing

See overview of measuring reference system in section 1.1.5.

I/O

Input and/or output

Jog mode

Manual positioning in positive or negative direction

Load voltage,
logic voltage

The load voltage supplies the power electronics of the motor controller
and thereby the motor. The logic voltage supplies the evaluation and
control logic of the motor controller as well as the local digital I/Os
(see section 3.2).

Logic 0

0 V present at input or output (positive logic, corresponds to LOW).