5. Commissioning

5−12

Festo GDCP−SFC−LACI−CO−EN en 0812NH

5.2.2

Setting the homing parameters

The homing point is determined as follows, depending on the
homing method:

ć

by means of the drive’s integrated reference switch with a
subsequent index search (recommended) or

ć

by means of a fixed stop (to be fitted externally by the
customer).

For homing to the switch, only the drive’s integrated referĆ
ence switch can be selected on the control panel. Use the FCT
for parameterising if you require further options.

The homing process is described in section 1.1.6.

You can set two different speeds for searching for the
reference point and for the subsequent run to the axis zero
point. The maximum possible speed is subject to built−in
limits.