Festo Контроллеры двигателя SFC-LAC User Manual

Page 318

Advertising
background image

B. Parametrising as per FHPP−FPC

B−90

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Output stage temperature

PNU

1066

ć

int16

r

Description

Temperature of the SFC−LACI output stage. Range: −20...+120 °C.

CI / DS402

6

510h

31h

int16

r

Output stage max temp

PNU

1067

ć

int16

r

Description

Highest temperature measured to date for the SFC−LACI, in °C. Stored in
EEPROM.

CI / DS402

6510h

32h

int16

r

Output stage lower threshold temperature

PNU

1068

ć

uint16

rw

Description

Lower temperature threshold for SFC−LACI: 80 °C
A warning is triggered when this temperature is reached.

CI / DS402

6510h

33h

uint16

rw

Output stage upper threshold temperature

PNU

1069

ć

uint16

rw

Description

Upper temperature threshold for SFC−LACI: 85 °C. When this temperature is
reached, an error message is triggered. Restart only after the temperature has
dropped below the lower threshold (see PNU 1068).

CI / DS402

6510h

34h

uint16

rw

Advertising