B−65

Festo GDCP−SFC−LACI−CO−EN en 0812NH

Force mode

Stroke limit

PNU

510

ć

uint32

rw

Description

Maximum permitted stroke with force control. The distance of the actual position
from the start position must not be more than the amount specified in this
parameter. In this way you can ensure that, if force control is activated by mistake
(e.g. missing work item), the axis will not perform an uncontrolled movement. This
parameter is taken into account in all control modes in which the position
controller is not active in the status Operation enabled". Monitoring can be
deactivated when bit RCB1.B5 is set.

CI / DS402

60F6h

0

1h

uint32

rw

Min. torque/force (min. permitted force/torque)

PNU

511

ć

uint16

r

Description

The lowest permitted torque of the motor in per mill of the rated value (6076h /
PNU1036). Fixed = 300.

CI / DS402

60F6h

0

5h

uint16

r

Max. torque/force (max. permitted force/torque)

PNU

512

ć

uint16

rw

Description

The highest permitted torque of the motor in per mill of the rated value (6076h /
PNU 1036). Values: 0...1000.

CI / DS402

6072h

00h

uint16

rw

Torque/force profile type

PNU

513

ć

int16

r

Description

Type of profile with which a force modification is undertaken. Fixed = 0: linear
ramp.

CI / DS402

6088h

00h

int16

r