Festo Контроллеры двигателя SFC-LAC User Manual
Page 323
![background image](/manuals/464473/323/background.png)
B. Parametrising as per FHPP−FPC
B−95
Festo GDCP−SFC−LACI−CO−EN en 0812NH
Local digital output 2 ć direction value ON
PNU
1255
ć
ć
uint32
rw
Description
Out2: Edge type for setting condition. See section 5.6.10.
CI / DS402
2422h
06h
uint8
rw
Local digital output 2 ć direction value OFF
PNU
1256
ć
ć
uint8
rw
Description
Out2: Edge type for resetting condition. See section 5.6.10.
CI / DS402
2422h
07h
uint8
rw
Local digital output 2 ć delay
PNU
1257
ć
ć
uint16
rw
Description
Out2: Delay time for resetting. See section 5.6.10.
CI / DS402
2422h
08h
uint16
rw
Local digital output 2 ć inverted
PNU
1258
ć
ć
uint8
rw
Description
Out2: Invert. See section 5.6.10.
CI / DS402
2422h
09h
rw
Local digital output 2 ć PWM value
PNU
1259
ć
ć
uint16
rw
Description
Out2: PWM value. See section 5.6.10.
CI / DS402
2422h
0Ah
uint16
rw