Yaskawa MP920 User's Manual Design User Manual

Page 124

Advertising
background image

4 Motion Control

4.2.2 Speed Reference Output Mode

4-10

* 1. Valid only with an SVB-01 Module.
* 2. Valid only with an SVA-02A Module.

2. Set the motion parameters.

The following three methods can be used to set the setting parameters.

• Using the MPE720 Setting Parameter Window
• Using a ladder logic program
• Using a motion program

* Valid only with an SVA-02A Module.

Table 4.1 Examples of Fixed Parameters

No.

Name

Setting Range

Meaning

Setting Example

7

Rated Motor Speed
Setting

1 to 32000

Rated motor speed

3000 r/min

8

Feedback Pulses per
Motor Rotation

4 to 65532

Number of pulses
before multiplica-
tion

2048 pulses/rev

9

D/A Output Voltage at
100% Speed

0.001 to 10.000

1 = 1 V

6.000 V

Feedback Pulses per
Motor Rotation
(for High-resolution)

*1

4 to 2147483647 1 = 1 pulse/rev

2048 pulses/rev

10 D/A Output Voltage at

100% Torque Limit

*2

0.001 to 10.000

0.001 = 0.001 V
1 = 1 V

3.000 V

Examples of Setting Parameters

Name

Register

No.

Setting

Range

Meaning

Setting

Example

Positive Torque Limit
Setting
(TLIMP)*

OW††02

-32768 to
32767

1 = 0.01%

-10000
(-100.00%)

Positive Speed Limiter
Setting (NLIMP)

OW††04

0 to 32767

1= 0.01%

13000
(130.00%)

Negative Speed
Limiter Setting
(NLIMN)

OW††05

0 to 32767

1= 0.01%

13000
(130.00%)

Linear Acceleration
Time Constant
(NACC)

OW††0C

0 to 32767

Linear acceleration time
constant (ms) at speed
pattern generation

1000
(1 second)

Linear Deceleration
Time Constant
(NDEC)

OW††0D

0 to 32767

Linear deceleration time
constant (ms) at speed
pattern generation

1000
(1 second)

Filter Time Constant
Setting
(NNUM)

OW††14

0 to 255

For simple S-curve
acceleration

0

Speed Reference
Setting
(NREF)

OW††15

-32768 to
32767

Speed reference value
1= 0.01%

5000
(50.00%)

Advertising