3 specifications of battery module – Yaskawa MP920 User's Manual Design User Manual

Page 480

Advertising
background image

11 Maintenance and Inspection

11.3.3 Specifications of Battery Module

11-8

11.3.3

Specifications of Battery Module

The table below shows the specifications of the Absolute Encoder Battery Module.

Specifications of Battery Module

Item

Specifications

Name

Absolute Encoder Battery Module

Model

JRMSP-120XCP96000

Maximum number of axes
to which power can be
supplied

8 axes

Indicators

POWER: Lit when external 24 VDC power is supplied to CN1 con-
nector. This indicator is not lit while a battery voltage check refer-
ence is being issued.
ALARM1: Lit when the battery voltage drops below 3.3 V.
ALARM2: Lit when the battery voltage drops below 3.0 V.

Battery Specifications

Model: ER6VC3 Battery (Toshiba) with connector (Yaskawa speci
fications)
Voltage: 3.6 V
Current capacity: 2,000 mAh

Maximum number of days
in which battery must be
replaced after low battery
voltage is detected

14 days after the ALARM1 indicator lights up (battery voltage drops
below 3.3 V), provided that all eight axes are connected, no power is
supplied to the Motion Module or Servo Amplifier, and the motor
does not rotate due to external force, etc.

External Input Signal

Signal type: 24 VDC, sourcing input (sinking input)
Input current: 5 mA
OFF current (1 mA or less)
Input conditions: ON voltage (supply voltage: -9 V) or more
(sinking: 9 V or more), OFF voltage (supply
voltage: -5 V) or less
Input impedance: 4.7 k

Signal
name

CHK

Battery voltage check reference. This signal
checks battery voltage when turned ON.

External Output Signal

Signal type: 24 VDC, sinking output (open collector)
Load current: 50 mA, OFF current (1 mA or less)
Load voltage: 20.4 to 28.8 VDC, 35 VDC (at peak), ON voltage
(1.5 V, 50 mA)

Signal
names

ALM1

Alarm 1. This signal is turned OFF when
battery voltage drops below 3.3 V.

ALM2

Alarm 2. This signal is turned OFF when
battery voltage drops below 3.0 V.

PON

Power ON. This signal is ON while 24 VDC
external power is being supplied to CN1
connector. This signal is OFF while battery
voltage check reference is being issued.

Delay Time

Power ON

→ ALM1/ALM2 output: 100 ms or less

CHK signal input

→ ALM1/ALM2 output: 10 ms or less

Protective Circuit

Battery charging prevention diode

Supply Voltage

20.4 to 28.8 VDC (external power supply)

Current Consumption

0.2 A or less

Advertising