background image

4 Motion Control

4.4.1 Overview of Motion Commands

4-46

3

Zero Point Return
(ZRET)

Returns the system to the machine coordinate system zero point. Eight zero return
modes are provided.

4

Interpolation
(INTERPOLATE)

Performs interpolation feeding using the position data distributed from the CPU
Module.

5

Not used.

This command is used by the system.
Do not use it in a user program.

6

Interpolation with
Position Detection
(LATCH)

Latches a counter when a latch signal is input during an interpolation feed operation,
and reports the changed latch position to the reference unit system.

(cont’d)

Command

Name

Description

0

1.

2.

3.

4.

Reverse direction

← → Forward direction

Zero point

Speed
reference

Approach
speed

Rapid traverse
speed

Creep speed

Zero point return position

Dog
(Deceleration limit switch)

Zero point signal
(C-phase pulse)

Time

Zero point return final
travel distance

Speed

(%)

0

POSCOMP

Position

Time (t)

Positioning completed range

Speed

(%)

0

POSCOMP

(IL

06)

Reports this position.

Latch signal

Position

Time (t)

Positioning completed range