4 Motion Control
4.4.1 Overview of Motion Commands
4-46
3
Zero Point Return
(ZRET)
Returns the system to the machine coordinate system zero point. Eight zero return
modes are provided.
4
Interpolation
(INTERPOLATE)
Performs interpolation feeding using the position data distributed from the CPU
Module.
5
Not used.
This command is used by the system.
Do not use it in a user program.
6
Interpolation with
Position Detection
(LATCH)
Latches a counter when a latch signal is input during an interpolation feed operation,
and reports the changed latch position to the reference unit system.
(cont’d)
Command
Name
Description
0
1.
2.
3.
4.
Reverse direction
← → Forward direction
Zero point
Speed
reference
Approach
speed
Rapid traverse
speed
Creep speed
Zero point return position
Dog
(Deceleration limit switch)
Zero point signal
(C-phase pulse)
Time
Zero point return final
travel distance
Speed
(%)
0
POSCOMP
Position
Time (t)
Positioning completed range
Speed
(%)
0
POSCOMP
(IL
06)
Reports this position.
Latch signal
Position
Time (t)
Positioning completed range