11 Maintenance and Inspection

11.3.5 Connecting to SVA-01A Module

11-14

„

Connector Pin Layout

1CN: External Power Supply/External I/O Connector

The external power supply/external I/O connector (1CN) connects +24 V external power
supply, alarm output, battery voltage check input, and so on. The pin layout of this connector

is shown below.

2CN: Battery Voltage Output Connector

The battery voltage output connector (2CN) supplies backup power to the Absolute Encoder

through the SVA-01A Module. The pin layout of this connector is shown below.

Connector Model: MR-16F (Soldered, Manufactured by HONDA TSUSHIN KOGYO)

6

024V

External power input

16

+24V

External power input

5

024V

External power input

15

+24V

External power input

10

Not

used

4

PONG

Power ON GND

14

PON

Power ON output

9

Not

used

3

ALM2G Voltage drop 1 GND

13

ALM2

Voltage drop 1 output

8

Not

used

2

ALM1G Voltage drop 2 GND

12

ALM1

Voltage drop 2 output

7

Not

used

1

CHKG

Battery voltage
check GND

11

CHK

Battery voltage check
input

Connector Model: MR-20M (Soldered, Manufactured by HONDA TSUSHIN KOGYO)

1

BATG

Battery voltage GND

14

BAT

Battery voltage out-
put

8

Not
used

2

BATG

Battery voltage GND

15

BAT

Battery voltage out-
put

9

Not
used

3

BATG

Battery voltage GND

16

BAT

Battery voltage out-
put

10

Not
used

4

BATG

Battery voltage GND

17

BAT

Battery voltage out-
put

11

Not
used

5

BATG

Battery voltage GND

18

BAT

Battery voltage out-
put

12

Not
used

6

BATG

Battery voltage GND

19

BAT

Battery voltage out-
put

13

Not
used

7

BATG

Battery voltage GND

20

BAT

Battery voltage out-
put