1 reference unit – Yaskawa MP920 User's Manual Design User Manual

Page 419

Advertising
background image

8 Controlled Axis Support Functions

8-2

8.1

Reference Unit

A reference unit is the unit of measure used for positioning. In the MP920, the reference unit
can be millimeters, degrees, inches, or pulses. It is also referred to as a minimum reference unit
when it expresses the minimum measurement unit for a position. The minimum reference unit is
determined by two fixed parameters: Reference Unit Selection and Number of Digits Below
Decimal Point.

The fixed parameter: Number of Digits Below Decimal Point is disabled when the pulse unit is
selected.

Table 8.1 Reference Units

Number of Digits

Below Decimal

Point

Reference Unit (Electronic Gear Enabled)

Pulse

(Electronic Gear

Disabled)

mm

deg

inch

0

1[mm]

1[deg]

1[inch]

1[pulse]

1

0.1[mm]

0.1[deg]

0.1[inch]

2

0.01[mm]

0.01[deg]

0.01[inch]

3

0.001[mm]

0.001[deg]

0.001[inch]

4

0.0001[mm]

0.0001[deg]

0.0001[inch]

5

0.00001[mm] 0.00001[deg]

0.00001[inch]

IMPORTANT