10 Absolute Position Detection

10.3.2 Infinite Length Mode Axis

10-20

„

Setting the Zero Point for an Infinite Length Mode Axis

Execute the ZSET motion command (zero point setting).

The system will check pulse position at power OFF, encoder position at power OFF, and all
position data when the zero point is set.

The following illustration shows the procedure for setting the zero point for an Infinite
Length Mode Axis.

* 1. With an Infinite Length Mode Axis, the setting parameter OL††06:

Zero Point Offset is only enabled when the ZSET command is exe-
cuted. Therefore, the OL††06 value must be set at the M register.
Set the desired coordinates at Zero Point Offset (OL††06) when
using an Infinite Length Mode Axis.
Example:
When setting the current stop position to 0 (zero point position for the
machine coordinate system)
0

→ OL††06

* 2. Execute with the ZSET command.

YES

NO

Start

Servo ON

JOG to move close to the

zero point.

STEP to move to the

zero point.

Has the setting for the required

axis been completed?

Set the desired position at OL

06.

*1

Set the zero point.

*2

Repeat for every axis.

End