3 motion errors, 1 description of motion errors, 2 processing flow when a motion error occurs – Yaskawa MP920 User's Manual Design User Manual

Page 509: Troubleshooting flow

Advertising
background image

12.3 Motion Errors

12-19

12

12.3 Motion Errors

This section describes the details and remedies for errors that occur in motion functions.

12.3.1

Description of Motion Errors

Motion errors in the MP920 are classified as alarms detected in motion programs and axis
alarms detected in SERVOPACK units.

The failure location can be determined and appropriate corrections can be taken simply by
checking the contents of the alarm output register set from the Define Group Screen for
motion program alarms and the contents of monitor parameter: Alarms (IL††22) for axis
alarms.

12.3.2

Processing Flow When a Motion Error Occurs

„

Troubleshooting Flow

The following illustration shows the troubleshooting flow when a motion error occurs.

START

Yes

System error

NO

YES

Motion progarm
alarm

No

Yes

No

YES

NO

YES

Axis alarm

NO

All LEDs on the MC

Module as well as ERR

and ALM LEDs lit?

H01 Screen display

Axis alarm has occurred.
Group alarm has occurred.

Motion control

ladder used?

Go to 12.2.2 Processing

Flow When a System

Error Occurs.

Display alarm output register

contents. (Display HEX (H)

on the register list.)

Determine the cause from

the alarm code.

See the List of Alarm Codes.

Display monitor parameter:

Alarm (IL

22).

Determine the cause from

alarm bits.

Alarm occurred?

Axis alarm

occurred?

Alarm output register

= 0

Axis alarm present

(IL

22 = 0)?

No alarm

No alarm

= 0

≠ 0

System error

Advertising