12.3.2 Processing Flow When a Motion Error Occurs

12-22

„

Motion Parameter: Alarm IL††22 Details

The following tables lists the axis alarm flags (IL††22).

Parameter No.

Contents

Remedy

b0:

Not used

b1: OTF

Positive Overtravel

• Servo Amp overtravel in the positive direction detected

(P_OT signal ON)

b2: OTR

Negative Overtravel

• Servo Amp overtravel in the negative direction detected

(N_OT signal ON)

b3: SOTF

Positive Software Limit

• Machine movement toward the positive software limit range

detected

b4: SOTR

Negative Software Limit

• Machine movement toward the negative software limit range

detected

b5:

Not used

b6: TIMEOVER

Positioning Time Exceeded

• Positioning was not completed in the time set at OW††34:

Positioning Complete Check Time after distribution.

b7:

Not used

b8:

Not used

b9:

Not used

b10: MODERR

Control Mode Error

• A Position Control Mode motion command is used in a mode

other than position control.

b11: ZSET_NRDY Zero Point Not Set

• When an Absolute Encoder was used, the zero point is not set

and a move was executed without a set zero point.

b12:

Not used

b13:

Not used

b14:

Not used

b15:

Not used

b16:

Not used

b17:

ABS Encoder Rotation Count Over

• The number of ABS encoder rotations exceeded the range of

the MP920.

b18: PGLEFT

Broken PG Wiring

• Broken PG wiring was detected when the A/B mode was

selected as a pulse calculation mode.

b19 to b31:

Not used