A.3.3 motion monitor parameters – Yaskawa MP920 User's Manual Design User Manual

Page 547

Advertising
background image

Appendix A

A.3.3 Motion Monitor Parameters

A-32

A.3.3

Motion Monitor Parameters

The following table lists motion monitor servo parameters.

No.

Name

Register

Number

Setting

Range

Meaning

Control Mode Where Data Is Valid

Zero Point Return Mode

S

pee

d Control Mode

To

rq

ue Control

Mod

e

Pha

se C

ontrol

Mode

Position Control Mode

Motion Command

Code (OB††008)

Motion

Co

mma

nd

Disab

led

Motion Command
Code (OW††20)

Positioning

External

Posi

tion

Zero Poin

t Return

Interpol

ation

La

tch

F

eed

St

ep

1

RUN Status
(RUNSTS)

IW††00

Reports the SVA Module operation status.

2

General-purpose
DI Monitors
(SVSTS)

IW††01

Reports the status of general-purposeDI signals, or input signals from SERVOPACK.

3

Calculated Posi-
tion in Machine
Coordinate
System
(CPOS)

IL††02

-2

31

to 2

31

-1

1 = 1 pulse or 1 = 1 reference
unit
1 = 1 pulse for pulses
Updated when the machine is
locked.

√ √ √ √ √ √ √ √ √

5

Target Position
Difference Mon-
itor (PTGDIF)

IL††04

-2

31

to 2

31

-1

1 = 1 pulse or 1 = 1 reference
unit
1 = 1 pulse for pulses

√ √ √ √ √ √ √ √ √

7

Machine Coordi-
nate System
Latch Position
(LPOS)

IL††06

-2

31

to 2

31

-1

1 = 1 reference unit
(1 = 1 pulse for pulses)

√ √ √ √ √ √ √

√ √ √ √

9

Machine Coordi-
nate System
Feedback Posi-
tion (APOS)

IL††08

-2

31

to 2

31

-1

1 = 1 reference units
(1 = 1 pulse for pulses)

Note: Will not be updated if

the machine is locked.

√ √ √ √ √ √ √ √ √ √ √ √

11

Position Error
(PERR)

IL††0A

-2

31

to 2

31

-1

1 = 1 reference unit
(1 = 1 pulse for pulses)

√ √ √ √ √ √ √ √ √

13

Speed Reference
Output Monitor
(SPDREF)

IW††0C

-32768 to
32767

1 = 0.01%

√ √ √ √ √ √ √ √ √ √ √ √

14

Speed Monitor
(NFB)

IW††0D

-32768 to
32767

1 = 0.01%
Note: Valid only with a 2-axis

SVA Module.

√ √ √ √ √ √ √ √ √ √ √ √

15

Not used

IW††0E

16

Out of Range
Parameter Num-
ber (ERNO)

IW††0F

1 to 63
101 to 148

Set motion parameter error
number
Fixed motion parameter error
number

√ √ √ √ √ √ √ √ √ √ √ √