Yaskawa MP920 User's Manual Design User Manual

Page 463

Advertising
background image

10 Absolute Position Detection

10.3.1 Finite Length Mode Axis

10-18

„

The following methods are used to save the Zero Point Offset (OL††06).

• Saving in a Ladder Logic Program M Register

Calculate (-(calculated position monitored in the machine coordinate system) + the Zero Point
Offset) and save the results in the M register when they are stored at OL††06.
Store the contents saved in M register at setting parameter OL††06: Zero Point Offset when sys-
tem or servo power is turned back ON.
Ladder Logic Program Required for a Finite Length Mode Axis: ABS System Finite Length Mode
Axis (Axis No. 1)

• Saving the OL††06: Zero Point Offset from the MPE720 Parameter Window

After the zero point and the Zero Point Offset (OL††06) value (current value) are set, use SAVE
to save the settings to the Controller. When power is turned back ON, the value that was saved for
Zero Point Offset (OL††06) will be stored automatically.

INFO

IFON

OLC006

IB000106

Zero Point Setting signal startup detection

Zero point position offset - calculated position monitor in the
machine coordinate system is stored in OL

06.

Save in M register.

Store the offset saved in M register in OL

06.

DB000000

ILC002

OLC006

ML00400

IEND

ML00400

OLC006

DEND

Advertising