10 Absolute Position Detection

10.2.2 Setting Related Parameters

10-8

Number of Feedback Pulses per Motor Rotation/Number of Encoder
Pulses/PG Dividing Ratio

• MP920 fixed parameter No. 8
• SERVOPACK parameter Cn-0011, Pn201

Set the number of absolute encoder pulses in the MP920 fixed parameter No. 8 and SERVO-

PACK parameter Cn-0011 or Pn201 as shown in the table below.

* When using an SVA-01 or SVA-02 Module in combination with an

encoder of 16 bits or more, rotating the servomotor at 3,000 min

-1

or

faster may cause errors in counting pulses because the response fre-
quency exceeds 1 MHz.
To avoid such errors, make settings for 15-bit encoder.
(The SVA-01A and SVA-02A hardware version B5 or later supports the
response frequency 1.5 MHz. For these models, the settings for 16-bit
encoder can be used.)

Be sure to set both MP920 parameter and SERVOPACK parameter since the both parame-
ters are used.

If the above parameters are not correctly set, the motion control will not be performed correctly.

Σ-II Series SERVOPACK Selection

• MP920 SVA-01A/SVA-02A Module fixed parameter No. 14, bit 9

Set the above bit to ON when the MP920 SVA-01A/SVA-02A Module is connected to

Σ

-II

series SERVOPACK.

Set to OFF when the MP920 SVA-01A/SVA-02A Module is connected to

Σ

series SERVO-

PACK.

If the above parameters are not correctly set, the position may be shifted.

No. of Bits

MP920

Fixed Parameter No. 8

SERVOPACK Parameter

(

Cn-0011/Pn201)

12

1024

1024

13

2048

2048

14

4096

4096

15

8192

8192

16 or more

16384 *

16384 *