4.3 Position Control

4-35

4

With the SVA-02A (2-axis Servo Module), there are position buffers for only 2 axes.

Using the Position Buffers

1. By first storing in the position buffers the position information for a machine whose

operating pattern has been determined in advance, continuous positioning of up to 256
points is enabled simply by refreshing the buffer pointer at the completion of a single-
block operation.

Writing to Position Buffers

a) Set the Position Buffer Access Number (OL††38)(1 to 256).

b) Set the Position Buffer Write Data (OL††3A).

c) Set the Position Buffer Write (OB††21E) in the Motion Command Control Flags to

ON.

Axis 1 position buffers

1

2

3

256

1

2

3

256

1

2

3

256

1

2

3

256

Axis 2

Axis 3

Axis 4

CPU Module

SVA Module

RUN Command Settings

Position Reference Setting

Motion Control Flags

Position Buffer Access Number

Position Buffer Write Data

Position Buffer Read Data

.
.
.
.
.

OW

01

OL

12

OW

21

OL

38

OL

3A

IL

28

INFO

CPU Module

96

123456

OW

21

OL

38

OL

3A

1

2

3

256

1

2

3

256

1

2

3

256

1

2

3

.
.
.
.
.
.

256

96

.
.
.

123456

SVA Module

Axis 2

Axis 3

Axis 4

Axis 1 position buffers