4 Motion Control

4.2.4 Phase Control Mode

4-16

„

Details

Use the following procedure to perform phase control operation.

1. Set the motion fixed parameters according to the user’s machine.

* 1. Valid only with an SVB-01 Module.
* 2. Valid only with an SVA-02A Module.

2. Set the motion parameters. Use the user program to control the reference speed so that no

shock occurs.

The following three methods can be used to set the setting parameters.

• Using the MPE720 Setting Parameter Window
• Using a ladder logic program
• Using a motion program

Table 4.5 shows the related parameters when the phase control mode is used.

Table 4.4 Examples of Fixed Parameters

No.

Name

Setting Range

Meaning

Setting Example

7

Rated Motor Speed
Setting

1 to 32000

Rated motor speed

3000 r/min

8

Number of Feedback
Pulses per Motor Rotation

4 to 65532

Number of pulses
before multiplica-
tion

2048 pulses/rev

9

D/A Output Voltage at
100% Speed

0.001 to 10.000

1 = 1 V

6.000 V

Feedback Pulses per
Motor Rotation
(for High-resolution)

*1

4 to 2147483647 1 = 1 pulse/rev

2048 pulses/rev

10 D/A Output Voltage at

100% Torque Limit

*2

0.001 to 10.000

0.001 = 0.001 V
1 = 1 V

3.000 V

1. Set the motion fixed parameters.

2. Set the motion setting parameters.

3. Select the phase control mode (PHCON).

4. Set the RUN command (RUN) to ON.

PCON

RUN

0

5. Set the phase control mode to OFF.

(100%)

Phase control operation is performed.

Time (t)

Speed (%)

Reference

speed

Position

: System execution

: User settings