2 position control without using motion commands – Yaskawa MP920 User's Manual Design User Manual

Page 155

Advertising
background image

4.3 Position Control

4-41

4

2. Speed Reference Value Selection Set to “1”

a) When you wish perform operations with the fixed parameters set for a rapid traverse

speed of 1,500 r/min, an approach speed of 300 r/min, and a creep speed of 150 r/min,
use the following settings.

• OW††0A = 10,000 (100%)

b) When you wish to leave the above speed reference settings unchanged, but halve the

operating speed, use the following setting.

• OW††2C = 5,000 (50.00%)

4.3.2

Position Control Without Using Motion Commands

„

Overview

Position control performs speed acceleration/deceleration according to the related parame-
ters, and positions the axis to the target position of the position reference setting parameter
(OL††12).

The position control without using motion commands is not applicable for SVB-01 and PO-01 Mod-
ules. Always set the parameters to enable the motion commands for the position control using SVB-01
or PO-01 Module.

OW

0A =

× 10,000 = 1,000 (10.00%)

300 (r/min)

3,000 (r/min)

OW

0B =

× 10,000 = 500 (5.00%)

150 (r/min)

3,000 (r/min)

OW

15 =

× 10,000 = 5,000 (50.00%)

1,500 (r/min)
3,000 (r/min)

OW

22 = (Invalid)

IMPORTANT

Advertising