7.1 Description of Parameters
7-3
7
Refer to the MP920 Machine Controller User's Manual: Motion Modules (SIEZ-C887-2.5) for details
on SVB and PO Module parameters.
7.1.2
Module Numbers and Motion Parameter Register Numbers
The motion parameter register numbers (I register numbers and O register numbers) will
vary with the motion number and the individual axis (axis 1 to 4).
The following equation is used to determine motion parameter register numbers.
• Motion register number (IW and OW) = Motion number offset + axis
offset.
• The following are Module number offsets listed by Module number.
The following equations gives the axis offsets according to the axis number.
INFO
Module No.
Offset Value
Module No.
Offset Value
1
C000
9
E000
2
C400
10
E400
3
C800
11
E800
4
CC00
12
EC00
5
D000
13
F000
6
D400
14
F400
7
D800
15
F800
8
DC00
16