A.4.2 monitoring parameter number 23 alarms – Yaskawa MP920 User's Manual Design User Manual

Page 552

Advertising
background image

A.4 Monitoring Parameter Alarms

A-37

A

A.4.2

Monitoring Parameter Number 23 Alarms

The following table shows the servo-related alarms for each axis.

Register

Number

Bit

Alarm Name

Cause

Action

IL††22

b0:

Not used

b1: OTF

Forward Overtravel

• Forward overtravel of the SERVO-

PACK was detected (P-OT signal
ON).

• Check the overtravel limit switch,

and bring it back in the opposite
direction after resetting the alarm.

• Check the overtravel input signal.
• Check the parameters relating to

overtravel alarm detection.

b2: OTR

Reverse Overtravel

• Reverse overtravel of the SERVO-

PACK was detected (N-OT signal
ON).

• Check the overtravel limit switch,

and bring it back in the opposite
direction after resetting the alarm.

• Check the overtravel input signal.
• Check the parameters relating to

overtravel alarm detection.

b3: SOTF

Positive Software
Limit

• Movement towards the positive

software limit area was detected.

• After checking the program and

operation, reset the alarm and
bring the switch back in the oppo-
site direction.

• Check the parameters relating to

the software limit.

b4: SOTR

Negative Software
Limit

• Movement towards the negative

software limit area was detected.

• After checking the program and

operation, reset the alarm and
bring the switch back in the oppo-
site direction.

• Check the parameters relating to

the software limit.

b5:

Not used

b6:
TIMEOVER

Positioning time
exceeded

• After the command was executed,

positioning could not be com-
pleted in the time set in
OW††34 (Positioning Com-
pleted Check Time).

• Check the parameters relating to

the servo characteristics (each
gain setting).

• Check the connections between

the SERVOPACK and motors.

b7:

Not used

b8:

Not used

b9:

Not used

b10:

Not used

b11:
SET_NRDY

No Zero Point

• No zero point has been set.

• Set the zero point.

b12 to b16:

Not used

b18:
PGLEFT

Broken PG Wiring

• Encoder wiring is faulty or broken.
• Encoder or SERVOPACK is

faulty.

• SVA Module is faulty.

• Check the encoder wiring.
• Contact your Yaskawa sales repre-

sentative.

b19:

Not used

Advertising