Pulse output module (po-01) – Yaskawa MP920 User's Manual Design User Manual

Page 43

Advertising
background image

2.1 Specifications

2-17

2

„

Pulse Output Module (PO-01)

Table 2.15 shows the hardware specifications of the PO-01 Pulse Output Module.

Table 2.15 Hardware Specifications of the PO-01 Pulse Output Module

Item

Specifications

Name

Pulse Output Module

Model Number

JEPMC-PL210

Description

PO-01

No. of Controlled
Axes

4

Pulse Output

Methods

Sign + pulse, pulse

Frequency

500 kpps max. (software switching)

Interface

5-V differential output

Other functions

Can be switched between positive and negative
logic by software.
Two emergency stopping method (immediate
stop/deceleration to a stop)

Digital Inputs

Photocoupler insulation, current sourcing mode input 5 points

× 4

channels

DI_0: Individual power supply

5 V/5 mA, 12 V/12 mA, or 24 V/5 mA

DI_1 to DI_4: Common power supply, 0.5 ms filter, 24 V/5 mA

Allocation example

DI_0

Zero point

DI_1

Dog signal/general-purpose

DI_2

Limit 1

DI_3

Limit 2

DI_4

Emergency stop/Deceleration to a stop

Digital Outputs

24-V open-collector (current sinking mode output)
4 points

× 4 channels

Photocoupler insulation, 100 mA max.

Allocation example

DO_0

Excitation ON

DO_1

General-purpose

DO_2

General-purpose

DO_3

General-purpose

Indicator

Module status 7-segment LED indicator (green)

Connectors

CN1

Axis-1 and -2 connector 10250-52A2JL

CN2

Axis-3, and -4 connector 10250-52A2JL

Hot Swapping (In-
sert/Remove while
power is being sup-
plied)

Not allowed.

Dimensions (mm)

40

× 130 × 105 (W × H × D)

Advertising