3 position control, 1 prerequisites for position control, Overview – Yaskawa MP920 User's Manual Design User Manual

Page 141

Advertising
background image

4.3 Position Control

4-27

4

4.3

Position Control

This section describes the prerequisites for position control, and position control without using
motion commands.

4.3.1

Prerequisites for Position Control

„

Overview

With position control, the axis is moved to the target position, stops there, and holds that
position (servo clamp).

An incremental encoder or a Yaskawa absolute encoder is used as the position detector.
When a Yaskawa absolute encoder is used, the absolute position is stored, even when the
power for the machine (positioning device) is disconnected. Therefore, when the power is
turned ON again, the zero point return operation is not required.

There are two position control methods. One method uses motion commands (OW††20),
and the other method does not use motion commands.

Whether or not motion commands (OW††20) are to be used is set in the motion parameters
shown in the following table.

Note: When bit 7 (motion command selection) of motion fixed parameter

No. 14 (Additional Function Selections) is not selected for use and bit
8 (motion command code enable) of the RUN Mode Settings
(OW††00) motion setting parameter is set to “1

(= enabled), the

axis is controlled without motion commands (OW††20).

The position control mode is applicable for any motion module. However, it is applicable for SVB-01
and PO-01 Modules, only when the motion commands are enabled. The table below shows the condi-
tions to use the position control mode for each module.

Motion Parameter

Motion Command

(OW††20) Not Used

Motion Command
(OW††20) Used

Motion fixed parameter No. 14
Bit 7 of Additional Function Selections
(Motion Command Selection)

0 (= Not used)

1 (= Used)

Motion setting parameter
Bit 8 of RUN Mode Settings (OW††00)
(Motion Command Code Enable/Disable)

0 (= Disabled)

1 (= Enabled)

Position Control Mode

Motion Command Enabled

Motion Command Disabled

SVA-01A

Applicable

Applicable

SVA-02A

Applicable

Applicable

SVB-01

Applicable

N/A

PO-01

Applicable

N/A

IMPORTANT

Advertising