10 Absolute Position Detection

10.3.1 Finite Length Mode Axis

10-16

„

Position Control with a Finite Length Mode Axis

Initialize the axis position as described next when power is turned ON if an absolute encoder
is used for a Finite Length Mode Axis.

Current position for the machine coordinate system =
(Encoder position when servo power is turned ON)*
+ Setting parameter OL††06: Zero Point Offset

* Multi-turn data

× the number of encoder pulses + initial increment

Setting parameter OL††06: Zero Point Offset is always enabled in Finite Length Mode.
This means that the current position of the machine coordinate system (zero point setting)
can be changed at any time.

The meaning of setting parameter OL††06 will depend on whether Finite Length Mode or
Infinite Length Mode is set.

Finite Length Mode

Set - (IL††02) + OL††06 at OL††06 in order to make the current position of the
machine coordinate system the zero position.

IL††02 = 10,000 and OL††06 = 100
Setting the current position of the machine coordinate system to 0 when the zero point is set.
-(10,000) + 100 = -9,900

OL††06 to -9,900

IL

††

02: Monitor the calculated position of the machine coordinate system

Infinite Length Mode

Set the desired position at OL††06 and that setting will be used for the current position of
the machine coordinate system when the zero point is set.

Setting the current position of the machine coordinate system to 0 when the zero point is set
Set OL††06 to 0.

EXAMPLE

EXAMPLE