2 operation, Connecting the mpe720 programming device, Fig. 9.2 multi-cpu system function block diagram – Yaskawa MP920 User's Manual Design User Manual

Page 430: Cpu module 1 cpu module 2

Advertising
background image

9.1 Overview

9-3

9

9.1.2

Operation

The CPU Module mounted in slots 0 and 1 of the Mounting Base is called CPU Module 1,
and the CPU Module mounted in the slots 2 and 3 of the Mounting Base is called CPU Mod-
ule 2. This section describes the functions and processing assigned to CPU Module 1 and
CPU Module 2 and the operation of the system.

„

Connecting the MPE720 Programming Device

It is possible to log on to both CPU Module 1 and CPU Module 2 from one MPE720 Pro-
gramming Device without changing the cable connection for engineering operations, such as
setup, programming, and register display. For example, it is possible to log on to both CPU
Module 1 and CPU Module 2 from a Programming Device connected to the RS-232C port
of CPU Module 1 or from a Programming Device connected via a Communications Module,
such as the 217IF, 218IFA, and 215IF. Logging on to both CPU Module 1 and CPU Module
2 is possible via a Communications Module no matter which CPU Module is specified as the
Control CPU Module described in Controlling Optional Modules in this section.

Fig. 9.2 Multi-CPU System Function Block Diagram

MPE720
Programming Device

MPE720
Programming Device

CPU Module 1

CPU Module 2

H scan

H scan

User ladder
/motion
programs

User ladder/
motion
programs

L scan

L scan

User ladder/
motion
programs

User ladder/
motion
programs

Data memory

Others

Data memory

M registers

I registers

O registers

S registers

I registers

O registers

S registers

Others

Configuration
data

(For CPU
Module 1)

(For CPU
Module 1)

(For CPU
Module 1)

(For CPU
Module 2)

(For CPU
Module 2)

(For CPU
Module 2)

Configuration
data

Motion

Modules

I/O Modules

Communications

Modules

(217IF,
218IFA,
215IF)

(DI, DO, AI, AO,
LIO, CNTR, etc.)

(SVA, SVB, PO)

M registers

Shared memory

H (high-speed) scans
can be synchronized.

L (low-speed) scans
can be synchronized.

Advertising