C-phase pulse, Dec1 + zero signal, Dec2 + zero signal method – Yaskawa MP920 User's Manual Design User Manual

Page 177

Advertising
background image

4.4 Position Control Using Motion Commands

4-63

4

„

C-phase Pulse

This method is used to perform zero point return using only a zero point signal (C-phase
pulse) by rapid traverse using linear acceleration/deceleration.

1. The axis travels at approach speed in the direction specified in the motion setting servo

parameter (OB††009).

2. The axis decelerates to creep speed after detecting the initial zero point signal.

3. The axis stops after traveling only the zero point return final travel distance from the ini-

tial zero point signal, and that position will be the machine coordinate system zero point.

„

DEC1 + ZERO Signal

This method can be used only with a 4-axis SVA-01 Module.

Zero point return is performed using a ZERO signal (DI signal) in place of the C-phase pulse
used in the DEC1 + C-phase Pulse described above.

For details, see DEC1 + C-phase Pulse.

„

DEC2 + ZERO Signal Method

This method can be used only with a 4-axis SVA-01 Module.

Zero point return is performed using a ZERO signal (DI signal) in place of the C-phase pulse
used in the DEC2 + C-phase Pulse discussed above.

For details, see DEC2 + C-phase Pulse.

1.

2.

3.

Reverse direction

← → Forward direction

Zero point

Speed
reference

Creep speed

Zero point
return position

Zero point signal
(C-phase pulse)

Zero point return final travel distance

Time

SVA-01A

SVA-02A

SVB-01

PO-01

Applicable

Applicable

Applicable

N/A

SVA-01A

SVA-02A

SVB-01

PO-01

Applicable

N/A

Applicable

Applicable

SVA-01A

SVA-02A

SVB-01

PO-01

Applicable

N/A

N/A

Applicable

Advertising