3 optimising the control mode, Optimising the control mode, 5motor control (mctrl) – Lenze 8400 motec User Manual

Page 100

Advertising
background image

5

Motor control (MCTRL)

5.5

V/f characteristic control (VFCplus)

100

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.5.3

Optimising the control mode

The V/f characteristic control (VFCplus) is generally ready for operation. It can be adapted

subsequently by adapting the characteristic and/or the drive behaviour.

Adapting characteristic
For the linear and quadratic characteristic, it is also possible to match its curve to different load

profiles or motors by adapting the V/f base frequency (

C00015

) and the V

min

boost (

C00016

).

Adapting the V/f base frequency

( 101)

Adapting the Vmin boost

( 102)

Adapting drive behaviour

• Limitation of the maximum current by a current limitation controller (e.g. to prevent the motor

from stalling or to limit to the maximally permissible motor current).

Optimising the Imax

controller

( 103)

• Adaptation of the field frequency by a load-dependent slip compensation (improved speed

accuracy for systems without feedback)