Parameter reference

11.2

Parameter list | C00976

406

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00976

C00977

C00978

C00979

C00980

Parameter | Name:

C00976 | VFC-ECO: Ti

Data type: UNSIGNED_16

Index: 23599

d

= 5C2F

h

Reset time of the Cos-Phi controller for energy-saving V/f characteristic control (

VFCplusEco

)

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

ms

6000.0 200.0 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Parameter | Name:

C00977 | VFC-ECO: Minimum voltage V/f

Data type: UNSIGNED_8

Index: 23598

d

= 5C2E

h

Minimum voltage V/f of the Cos-Phi controller for energy-saving V/f characteristic control (

VFCplusEco

)

Setting range

(min. value | unit | max. value)

Lenze setting

20

%

100 20 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00978 | VFC-ECO: Motor voltage sub

Data type: INTEGER_16

Index: 23597

d

= 5C2D

h

Display of the voltage reduction with energy-saving V/f characteristic control (

VFCplusEco

)

Display range

(min. value | unit | max. value)

-1000

V

1000

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00979 | Cosine phi

Data type: INTEGER_16

Index: 23596

d

= 5C2C

h

Display of the cosϕ setpoint and actual value with energy-saving V/f characteristic control (

VFCplusEco

)

Display range

(min. value | unit | max. value)

-1.00

1.00

Subcodes

Info

C00979/1

Cosine phi act

C00979/2

Cosine phi set

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00980 | Output power

Data type: INTEGER_32

Index: 23595

d

= 5C2B

h

Display parameter for an energy analysis in the prevailing application. From this, decisions can be deduced whether

a measure for energy optimisation is economic.
Display range

(min. value | unit | max. value)

0.000

kW

32.000

Subcodes

Info

C00980/1

Active output power

C00980/2

Apparent output power

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000