Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

123

5

Motor control (MCTRL)

5.8

Sensorless vector control (SLVC)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.8.1

Parameterisation dialog

Proceed as follows to open the dialog for parameterising the motor control:

1. »Engineer« Go to the Project view and select the 8400 motec controller.
2. Select the Application parameters tab from the Workspace.
3. Select the motor control "4: SLVC: Vector control" from the Overview dialog level in the

Motor control list field:

4. Click the Motor control vector button to change to the OverviewMotor control vector

dialog box.

• This dialog level lists shows all relevant parameters in a parameter list.

Short overview of the relevant parameters:

Parameter

Info

C00006

Selection of the motor control
 "4: SLVC: Vector control"

C00011

Reference speed

C00018

Switching frequency

C00021

Slip compensation

C00022

Imax in motor mode

C00023

Imax in generator mode

C00050

Speed setpoint

C00057

Maximum torque

C00058

Output frequency

C00081

Rated motor power

C00084

Motor stator resistance

C00085

Motor stator leakage inductance

C00087

Rated motor speed

C00088

Rated motor current

C00089

Rated motor frequency

C00090

Rated motor voltage

C00091

Motor cosine phi

C00092

Motor magnetising inductance

C00095

Motor magnetising current

C00097

Rated motor torque

C00105

Decel. time - quick stop

C00909/1

Max. pos. speed

C00909/2

Max. neg. speed

C00910/1

Max. pos. output frequency

C00910/2

Max. neg. output frequency

Highlighted in grey = display parameter