C00466 | keypad: default parameter, C00467 | keypad: default welcome screen, C00469 | keypad: fct. stop key – Lenze 8400 motec User Manual

Page 377: C00470 | ls_parfree_b, 11 parameter reference

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

377

11

Parameter reference

11.2

Parameter list | C00466

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00466

C00467

C00469

C00470

Parameter | Name:

C00466 | Keypad: Default parameter

Data type: INTEGER_32

Index: 24109

d

= 5E2D

h

Setting of the default parameter for the keypad
Setting range

(min. value | unit | max. value)

Lenze setting

0

65535 51

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00467 | Keypad: Default welcome screen

Data type: INTEGER_32

Index: 24108

d

= 5E2C

h

Selection of the welcome screen for the keypad
Selection list

(Lenze setting printed in bold)

0 Main menu
1 Parameter list

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00469 | Keypad: Fct. STOP key

Data type: INTEGER_32

Index: 24106

d

= 5E2A

h

Selection of the function for the STOP key on the keypad
Selection list

(Lenze setting printed in bold)

Info

0 No response

STOP key does not have any function

1 Inhibit controller

STOP key sets controller inhibit in the drive

2 Activate quick stop

STOP key sets quick stop in the drive

4 Inhibit controller and reset errors

From version 05.00.00

STOP key sets controller inhibit in the drive and errors are

reset.

5 Activate quick stop and reset errors

From version 05.00.00

STOP key sets quick stop in the drive and errors are reset.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00470 | LS_ParFree_b

Data type: UNSIGNED_8

Index: 24105

d

= 5E29

h

The

LS_ParFree_b

SB: Setting of the signal level to be output

Selection list

0 False
1 True

Subcodes

Lenze setting

Info

C00470/1

0: FALSE

Signal level for output bPar1 ... bPar16

C00470/...
C00470/16

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1