Parameter list | C00239

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00239

C00241

Parameter | Name:

C00239 | Limitation of lower speed

Data type: INTEGER_16

Index: 24336

d

= 5F10

h

From version 04.01.00

Here, a minimum lower setpoint speed can be set if, for example, the setpoint for pumps and fans should not fall

below a certain value. This prevents, e.g. a volume flow to be fallen below the minimum threshold.

• Compared to the setting "Min. analog setpoint" (

C00010/1

), this setting is scaled in [rpm] and is thus

independent of the reference speed set in

C00011

.

• This parameter can be used if old 8200 motec projects are migrated to the 8400 motec.

• In the Lenze setting "-9999 rpm", no limitation is active.

Note:

• Stopping commands such as DC-injection braking, quick stop and RFG_0 are executed independently of this

setting. Switch them off if you want to activate this setting.

• The maximum current controller can reduce the output frequency to below the minimum speed set here.

Setting range

(min. value | unit | max. value)

Lenze setting

-9999

rpm

9999 -9999 rpm

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00241 | L_NSet_1: Hyst. NSet reached

Data type: INTEGER_16

Index: 24334

d

= 5F0E

h

From version 04.00.00

Hysteresis window for setting the "speed setpoint reached" status

• Related digital signal in selection list: "62: LA_NCtrl_bSpeedSetReached"

• The reset hysteresis is permanently 0.5 %.

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

100.00 0.50 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100