C01501 | resp. to communication error with mci, C01503 | mci timeout, C01501/1 – Lenze 8400 motec User Manual

Page 418: C01501/2, C01503/1, 11 parameter reference

Advertising
background image

11

Parameter reference

11.2

Parameter list | C01501

418

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01501

C01503

Parameter | Name:

C01501 | Resp. to communication error with MCI

Data type: UNSIGNED_8

Index: 23074

d

= 5A22

h

Configuration of monitoring modes for the communication unit
Selection list

0 No Reaction
1 Fault
4 WarningLocked

Subcodes

Lenze setting

Info

C01501/1

1: Fault

Resp. to MCI error 1

• Response to a communication error.

C01501/2

1: Fault

Resp. to MCI error 2

• Response to an incompatible communication unit.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01503 | MCI timeout

Data type: UNSIGNED_16

Index: 23072

d

= 5A20

h

Setting range

(min. value | unit | max. value)

0

ms

1000

Subcodes

Lenze setting

Info

C01503/1

200 ms

MCI timeout

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1