Commissioning

3.7

PC manual control

54

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

How to easily rotate the motor:

1. Set the desired speed setpoint in [%] based on the reference speed, e.g. directly in the

Setpoint PC input field or via the slider.

• Via the -- / 0 / ++ buttons, the currently set speed setpoint can be reduced/increased in

steps of 10 percent or set to zero.

• Via the Set setpoint A/B buttons, the speed setpoint can be set to a previously set

constant value A/B.

2. To start the speed follower:

Enable the controller via the Enable controller button.

• Please observe that the controller will not be enabled if other sources of controller

inhibit (e.g. terminal RFR) are active.

• The enabled drive now follows the defined speed setpoint.
• In order to prevent shocks or overload at higher setpoint changes, the speed setpoint is

lead via a linear ramp generator with adjustable acceleration/deceleration time.

• Via the Inhibit controller button, the controller can be inhibited again, i.e. the motor

becomes torqueless and is coasting unless it already is at standstill.

Further functions:

• If the Set quick stop (QSP) button is clicked, the motor is braked to a standstill within the

deceleration time parameterised in

C00105

.

• Via the Deactivate quick stop (QSP) button, the quick stop can be deactivated.

• Via the << CCW and CW >> buttons, the direction of rotation can be changed.