5 pre-assignment of the application, 1 input connections, Pre-assignment of the application – Lenze 8400 motec User Manual

Page 220: Input connections, 7technology applications, 2 ta "actuating drive speed" 220

Advertising
background image

7

Technology applications

7.2

TA "Actuating drive speed"

220

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.2.5

Pre-assignment of the application

7.2.5.1

Input connections

Control modes 10 / 12 / 14 / 16 for control via terminals

Config.

parameter

Identifier

Control mode

10: Terminals 0

see chapter

[7.2.5.3]

12: Terminals 2

14: Terminals 11

16: Terminals 16

C700/1

nMainSetValue_a

AU

AU

AU

AU

C700/2

nTorqueMotLim_a

C472/3

C472/3

C472/3

C472/3

C700/3

nTorqueGenLim_a

C472/3

C472/3

C472/3

C472/3

C700/4

Key-operated switch: Max. speed

Poti P1

Poti P1

Poti P1

Poti P1

C700/5

Network(MCI/CAN)_wDriveControl

0x0009

0x0009

0x0009

0x0009

C700/6

nPIDVpAdapt_a

100 %

100 %

100 %

100 %

C700/7

nPIDActValue_a

-

-

-

-

C700/8

nPIDInfluence_a

100 %

100 %

100 %

100 %

C700/9

nPIDSetValue_a

-

-

-

-

C700/10

Reserved

-

-

-

-

C700/11

L_Counter_1

: wLdVal

-

-

-

-

C700/12

L_Counter_1

: wCmpVal

-

-

-

-

C700/13

L_Compare_1

: nIn1_a

-

-

-

-

C700/14

L_Compare_1

: nIn2_a

-

-

-

-

C700/15

LS_ParReadWrite_1

: wParIndex

-

-

-

-

C700/16

LS_ParReadWrite_1

: wParSubindex

-

-

-

-

C700/17

LS_ParReadWrite_1

: wInHWord

-

-

-

-

C700/18

LS_ParReadWrite_1

: wInLWord

-

-

-

-

C700/19

Reserved

-

-

-

-

C701/1

bCInh

-

-

-

-

C701/2

bFailReset

RFR

RFR

RFR

RFR

C701/3

bSetQuickstop

-

DI3

-

-

C701/4

bSetDCBrake

DI3

-

DI2

-

C701/5

bSetSpeedCcw

DI4

DI4

DI1

-

C701/6

bJogSpeed1

DI1

DI1

-

DI1

C701/7

bJogSpeed2

DI2

DI2

-

DI2

C701/8

bMPotUp

-

-

DI3

-

C701/9

bMPotDown

-

-

DI4

-

C701/10

bMPotInAct

-

-

-

-

C701/11

bMPotEnable

-

-

TRUE

-

C701/12

bRFG_0

-

-

-

-

C701/13

bSetError1

-

-

-

-

C701/14

bSetError2

-

-

-

-

C701/15

bPIDInfluenceRamp

TRUE

TRUE

TRUE

TRUE

C701/16

bPIDIOff

-

-

-

-

C701/17

bRLQCw

TRUE

TRUE

TRUE

DI3

C701/18

bRLQCcw

-

-

-

DI4

C701/19

bBrkRelease

DI5

DI5

DI5

DI5

C701/20

L_Counter_1

: bClkUp

-

-

-

-

C701/21

L_Counter_1

: bClkDown

-

-

-

-

C701/22

L_Counter_1

: bLoad

-

-

-

-

C701/23

L_DigitalDelay_1

: bIn

-

-

-

-

C701/24

L_DigitalDelay_2

: bIn

-

-

-

-

C701/25

LS_WriteParamList

: bExecute

-

-

-

-

Advertising