C02582 | holding brake: setting, C02582, Ally – Lenze 8400 motec User Manual

Page 423: Terised under, 11 parameter reference

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

423

11

Parameter reference

11.2

Parameter list | C02582

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02582

Parameter | Name:

C02582 | Holding brake: Setting

Data type: UNSIGNED_8

Index: 21993

d

= 55E9

h

Activation of functional holding brake control options

Holding brake control

Setting range

(min. hex value | max. hex value)

Lenze setting

0x00

0xFF 0x48 (decimal: 72)

Value is bit-coded: (= bit set)

Info

Bit 0  Control inverted

Activation of inverted control

• "1" ≡ Inverted logic of the trigger signal bBrkRelease

for triggering the power output (terminals BR1 and

BR2).

Bit 1  nAct < nMin at CInh

Brake response in case of pulse inhibit

• "1" ≡ In the case of a pulse inhibit, the actual speed

value is monitored which must reach the "Close"

threshold value to cause the holding brake to be

applied.

Note:

• Function only possible with available speed feedback

via the digital input terminals DI1/DI2.

• This function is only active if bit 3 (horizontal/

winding technology) is set as well. The function is

used in order that, when the controller is inhibited,

the holding brake of a drive with horizontal traverse

path does not wear out during rotation.

• With vertical motion (bit 3 = 0), this function is not

active. Especially with hoists and activated pulse

inhibit of the controller, an immediate application of

the brake is essential for safety-related reasons!

Bit 2  Inverted feedforward control

Direction of feedforward control with vertical/hoist

technology:

• "0" ≡ Positive direction

• "1" ≡ Negative direction

Note:

Reversal (Ccw) is then considered.

Bit 3  Horizontal/winding technology

Direction of movement of the axis

• "0" ≡ The axis performs vertical movements.

Gravitational acceleration causes movements.

• "1" ≡ The direction of the axis is horizontal or rotary.

The gravitational acceleration does not cause any

movement.

Bit 4  No premagnetisation

From version 02.00.00

Deactivation of the 200 ms premagnetisation before

releasing the brake.

• "0" ≡ Premagnetisation in case of feedforward

control.

• "1" ≡ No premagnetisation.

Bit 5  Reserved
Bit 6  SyncRamp OFF

From version 05.00.00

Selection of the ramp time for the synchronisation

process to setpoint speed after the brake opening time

has elapsed

Revised behaviour from version 05.00.00:

• "1" ≡ The ramp time of the effective acceleration of

the ramp function generator (

L_NSet_1

) is used

(Lenze setting).

• "0" ≡ As before, the ramp time set in

C02610/1

is used.

Note:

The changeover can be dynamically both via the ramp

parameter and via bit 6.

Advertising