Technology applications

7.2

TA "Actuating drive speed"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Configuration parameters for analog setpoints:

Display parameter:

bRLQCw

(

C00701/17

)

1:

LS_ParFix

: bTrue Activate clockwise rotation (fail-safe)

bRLQCcw

(

C00701/18

)

0: Not connected

Activate counter-clockwise rotation (fail-safe)

bSetSpeedCcw

(

C00701/5

)

14:

LS_DigitalInput

:

bIn4 (DI4)

Change of direction of rotation

bJogSpeed1

(

C00701/6

)

11:

LS_DigitalInput

:

bIn1 (DI1)

Selection of fixed setpoints (JOG setpoints)

bJogSpeed2

(

C00701/7

)

12:

LS_DigitalInput

:

bIn2 (DI2)

bPIDEnableInfluenceRamp

(

C00701/15

)

1:

LS_ParFix

: bTrue

L_PCTRL_1

: Activate ramp for influencing factor

bPIDIOff

(

C00701/16

)

0: Not connected

L_PCTRL_1

: Switch off I component

bPIDOff

(

C00701/35

)

0: Not connected

L_PCTRL_1

: Reset the entire PID controller

From version 04.00.00

bCInh

(

C00701/1

)

1:

LS_ParFix

: bTrue

Enable/Inhibit controller

bFailReset

(

C00701/2

)

15:

LS_DigitalInput

:

bCInh (RFR)

Reset error message

bSetQuickstop

(

C00701/3

)

0: Not connected

Enable quick stop (QSP)

bSetDCBrake

(

C00701/4

)

13:

LS_DigitalInput

:

bIn3 (DI3)

Parameter

Selection of signal source

(Lenze setting)

for setpoint selection:

nMainSetValue_a

(

C00700/1

)

10:

LS_AnalogInput

:

nIn1_a

(Analog input 1)

Main setpoint

• 100 % ≡ reference speed (

C00011

)

nPIDSetValue_a

(

C00700/9

)

0: Not connected

L_PCTRL_1

: Sensor setpoint or process setpoint for

operating mode 2

nPIDVpAdapt_a

(

C00700/6

)

1:

LS_ParFix

:

nPos100_a (100%)

L_PCTRL_1

: Adaptation of the gain Vp set in

C00222

in

percent

nPIDActValue_a

(

C00700/7

)

0: Not connected

L_PCTRL_1

: Actual speed value or actual sensor value

(actual process value)

nPIDInfluence_a

(

C00700/8

)

1:

LS_ParFix

:

nPos100_a (100%)

L_PCTRL_1

: Limitation of the influencing factor in

percent

Parameter

Info

nIn_a

(

C00830/11

)

Input value of motor potentiometer

nNset_a

(

C00830/1

)

Input value of setpoint generator

nOut_a

(

C00830/2

)

Output value of setpoint generator

nSpeedSetValue_a

(

C00830/2

)

Speed setpoint for motor control

nSet_a

(

C00830/8

)

Sensor setpoint or process setpoint for operating mode 2

Parameter