145

5

Motor control (MCTRL)

5.10

Parameterisable additional functions

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.10

Parameterisable additional functions

5.10.1

Selection of switching frequency

The switching frequency of the inverter that can be selected in

C00018

influences the smooth

running performance and the noise generation in the connected motor as well as the power losses

in the controller.
The lower the switching frequency the higher the concentricity factor, the smaller the losses, and

the higher the noise generation.

Short overview of the relevant parameters:

Stop!

If operated at a switching frequency of 16 kHz, the output current of the controller must

not exceed the current limit values specified in the technical data! (See chapter "Rated

data" of the hardware manual.)

Note!

• Operate mid-frequency motors only at a switching frequency of 8 kHz or 16 kHz (var./

drive-opt.).

• If operated at a switching frequency of 16 kHz, the Ixt evaluation (

C00064

) is

considered including the required derating to 67 % of the rated device current at

switching frequencies of 4 and 8 kHz.

• With a switching frequency of 4 kHz at a 400-V mains, the Ixt evaluation (

C00064

) is

considered with 120 % of the rated device current.

Parameter

Info

Lenze setting

Value Unit

C00018

Switching frequency

2: "8 kHz var./drive-opt."

C00144

Switching frequency reduction (temp.)

1: On

C00725

Current switching frequency

-

C00910/1

Max. pos. output frequency

300 Hz

C00910/2

Max. neg. output frequency

300 Hz

Highlighted in grey = display parameter