1 "generalpurpose" functions, Generalpurpose" functions, 7technology applications – Lenze 8400 motec User Manual

Page 205

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

205

7

Technology applications

7.2

TA "Actuating drive speed"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.2.1.1

"GeneralPurpose" functions

The following "GeneralPurpose" functions are freely available:

• The inputs of the "GeneralPurpose" functions can be linked to other output signals via the

configuration parameters of the application.

• On the other hand, the outputs of the "GeneralPurpose" functions can be selected in the

configuration parameters of other inputs.

How to open the parameterisation dialog of a "GeneralPurpose" function:
Go to the OverviewSignal flow dialog level and click the GP: GeneralPurpose >> dialog

box.

• Now, further buttons are displayed which are required for opening the parameterisation

dialog of the corresponding "GeneralPurpose" function:

• Renewed clicking on the GP: GeneralPurpose << button hides the additional buttons

again.

Related topics:

Application example: Debouncing a digital input

( 468)

Function block

Function

L_Compare_1

Analog comparison

L_Counter_1

Digital up/down counter

L_DigitalDelay_1

Binary delay element

(e.g. for debouncing a digital input)

L_DigitalDelay_2
L_DigitalLogic_1

Binary logic

(as of version 02.00.00)

L_DigitalLogic_2

Binary logic

(as of version 04.00.00)

LS_ParReadWrite_1

Reading and writing of local parameters

(from version 04.00.00 onwards)