Diagnostics & error management

9.8

Error messages of the operating system

308

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

oC11: Current clamp for too long (>1 sec) [xx.0123.00071]

ot2: Speed controller limitation [xx.0123.00093]

oC6: I2xt overload - motor [xx.0123.00105]

LP1: Motor phase failure [xx.0123.00145]

Sd10: Speed limit - feedback system 12 [xx.0123.00200]

Response (Lenze setting printed in bold)

No Reaction  Fault  Trouble  WarningLocked

Cause

Remedy

The device indicates that the "CLAMP" overcurrent limi-

tation has been activated.

• A permanent clamp operation causes an overload dis-

connection.

Reduce setpoint generation dynamics or motor load.

Response (Lenze setting printed in bold)

Setting:

C00567

( Adjustable response)

No Reaction  Fault  Trouble  WarningLocked

Cause

Remedy

The output of the speed controller has reached the inter-

nal limit value. In this status, the speed controller is not

able anymore to correct the system deviation.

• Only during "Closed loop" operation or with vector

control (SLVC).

• Observe load requirements.

• Correct dimensioning or reduce setpoint generation

dynamics if necessary.

Motor control

Response (Lenze setting printed in bold)

Setting:

C00606

( Adjustable response)

No Reaction  Fault  Trouble  WarningLocked

Cause

Remedy

Thermal overload of the motor.

Only self-ventilated motors can be monitored using the

I2xt function.

• Check whether it is a self-ventilated motor. If not, set

(

C00606

) to "0: No Reaction".

• Observe load requirements.

• Correct dimensioning if necessary.

• For VFCplus control type: Check Vmin boost (

C00016

).

Set Vmin boost

Response (Lenze setting printed in bold)

Setting:

C00597

( Adjustable response)

No Reaction  Fault  Trouble  WarningLocked

Cause

Remedy

Motor phase failure

Motor connections/check wiring unit.

Response (Lenze setting printed in bold)

Setting:

C00607

( Adjustable response)

No Reaction  Fault  Trouble  WarningLocked

Cause

Remedy

Maximally permissible speed of the feedback system

connected to DI1/DI2 reached.

Reduce speed of the rotation shaft/feedback system.

n

encoder

<= (f

max

x 60) / encoder increments

(for f

max

= 10 kHz)