2introduction: parameterising the controller – Lenze 8400 motec User Manual

Page 28

Advertising
background image

2

Introduction: Parameterising the controller

2.4

Handling the memory module

28

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Replacing the controller

• In the event of a device replacement, the entire parameter data of an axis can be copied to the

replacement device by "taking along" the memory module, so that additional PC or diagnosis

terminal operations are not required.

• When replacing the controller, the versions of the old device and the new device are of impor-

tance. Before data are actually transferred, the versions are internally checked. Basically, the fol-

lowing applies:

• Parameter sets of old devices with V 1.0 can be processed on new devices ≥ V 1.0

(downward compatibility).

• Parameters of devices with higher versions are not supported on devices with lower versions.

An error message will be issued if the parameter set versions of the two devices are not com-

patible.

Saving the parameters in the memory module safe against mains failure
Controller parameter changes via the »Engineer«, the diagnosis terminal, or a master control via

fieldbus communication will be lost after mains switching of the controller unless the settings have

been explicitly saved.
You have several options to avoid data loss by saving the parameter sets in the memory module:

Automatic saving of parameter changes

( 64)

Manual saving of parameter settings

( 64)

Parameter set transfer using the »Engineer«
When an online connection to the controller has been established, the following transfer functions

can directly be executed via the Toolbar or the Online menu using the L-force »Engineer«:

Tip!
Detailed information on parameter set transfers using the »Engineer« can be found in the

»Engineer« online help.

Icon

Menu command

Shortcut

Download parameter set

<F5>

Upload parameter set

<F7>

Save parameter set

Advertising