_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Configuration parameters for digital control signals:

Configuration parameters for analog setpoints:

Setting parameters:

Display parameter:

Parameter

Selection of signal source

(Lenze setting)

for control signal:

bCInh

(

C00701/1

)

0: Not connected

Enable/Inhibit controller

bFailReset

(

C00701/2

)

10:

LS_DigitalInput

:

bCinh

Reset error message

Parameter

Selection of signal source

(Lenze setting)

for setpoint selection:

nMainSetValue_a

(

C00700/1

)

80:

LS_Convert_1

:

Out1

Main setpoint via fieldbus (Ref from Net)

• 100 % ≡ reference speed (

C00011

)

nAuxSetValue_a

(

C00700/10

)

10:

LS_AnalogInput

:

nIn1_a

Local main setpoint

• 100 % ≡ reference speed (

C00011

)

nAuxTorqueValue_a

(

C00700/19

)

82:

LS_Convert_2

:

Out1

Torque setpoint via fieldbus (Ref from Net)

nTorqueMotLim_a

(

C00700/2

)

22:

LS_ParFree_a

:

nC472_3_a

Torque limitation in motor mode

nTorqueGenLim_a

(

C00700/3

)

23:

LS_ParFree_a

:

nC472_4_a

Torque limitation in generator mode

Parameter

Lenze setting

for setpoint selection:

Drive mode

(

C01350/1

)

1: Speed mode

This parameter is set by the EtherNet/IP™

Communication Unit and should not be written by the

user.

Parameter

Info

nNset_a

(

C00830/1

)

Input value of setpoint generator

• 100 % ≡ reference speed (

C00011

)

nOut_a

(

C00830/2

)

Output value of setpoint generator

• 100 % ≡ reference speed (

C00011

)

Speed setpoint

(

C00050

)

Speed setpoint for motor control

• 100 % ≡ reference speed (

C00011

)

nTorqueMotLimit_a

(

C00830/4

)

Torque limitation in motor mode

• 100 % ≡ maximum torque (

C00057

)

nTorqueGenLimit_a

(

C00830/5

)

Torque limitation in generator mode

• 100 % ≡ maximum torque (

C00057

)