C01206 | axis data: mounting direction, C01350 | acdrive: drive mode, C01206/1 – Lenze 8400 motec User Manual

Page 414: C01206/2, C01350/1, 11 parameter reference

Advertising
background image

11

Parameter reference

11.2

Parameter list | C01206

414

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01206

C01350

Parameter | Name:

C01206 | Axis data: Mounting direction

Data type: UNSIGNED_8

Index: 23369

d

= 5B49

h

From version 02.00.00

Inversion for mirrored motor and encoder mounting
Selection list

0 not inverted
1 inverted

Subcodes

Lenze setting

Info

C01206/1

0: Not inverted

Motor mounting direction

• Setting for motor mounting turned by 180°.

C01206/2

0: Not inverted

Position encoder mounting direction

• Setting for position encoder system mounting turned

by 180°.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01350 | ACDrive: Drive mode

Data type: UNSIGNED_8

Index: 23225

d

= 5AB9

h

From version 04.01.00

This parameter is set by the EtherNet/IP™ Communication Unit and should not be written by the user.

• Detailed information on the "AC Drive Profile" can be found in the EtherNet/IP™ communication manual.

Selection list

1 Speed mode
3 Torque mode

Subcodes

Lenze setting

Info

C01350/1

1: Speed mode

ACDrive: Drive mode

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1