I/O terminals

6.3

User-defined terminal assignment

196

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Example
Task: Based on the preset control mode "Terminals 0", the digital input DI2 is used for activating the

quick stop instead of selecting the fixed setpoint 2/3. For this purpose, the digital input DI2 must

not be linked to the bJogSpeed2 input but to the bSetQuickstop input of the application.
Procedure:

1. Change the setting of the configuration parameter LA_NCtrl: bSetQuickstop (

C00701/3

) which

represents the logical link of the bSetQuickstop application unit: "0: Not connected"  "12:

DigIn_bIn2"

2. Change the setting of the configuration parameter LA_NCtrl: bJogSpeed2 (

C00701/7

) which

represents the logical link of the bJogSpeed2 application unit: "12: DigIn_bIn2"  "0: Not con-

nected"

Tip!
The example shows that, for each input of a function, the associated configuration param-

eter (

C00700/x

or

C00701/x

) is only allowed to contain one source that you enter.

C00701/14

LA_NCtrl

: bSetError2

0: Not connected

C00701/15

LA_NCtrl

: bPIDInfluenceRamp

1: C_bTrue

C00701/16

LA_NCtrl

: bPIDIOff

0: Not connected

C00701/17

LA_NCtrl

: bRLQCw

1: C_bTrue

C00701/18

LA_NCtrl

: bRLQCcw

0: Not connected

C00701/19

LA_NCtrl

: bBrkRelease

15: DigIn_bIn5

C00701/20

L_Counter_1

: bClkUp

0: Not connected

C00701/21

L_Counter_1

: bClkDown

0: Not connected

C00701/22

L_Counter_1

: bLoad

0: Not connected

C00701/23

L_DigitalDelay_1

: bIn

0: Not connected

C00701/24

L_DigitalDelay_2

: bIn

0: Not connected

C00701/25

LS_WriteParamList

: bExecute

0: Not connected

C00701/26

LS_WriteParamList

: bSelectWriteValue_1

0: Not connected

C00701/27

Reserved

0: Not connected

C00701/28

L_DigitalLogic_1

: bIn1

0: Not connected

C00701/29

L_DigitalLogic_1

: bIn2

0: Not connected

C00701/30

L_DigitalLogic_2

: bIn1

0: Not connected

C00701/31

L_DigitalLogic_2

: bIn2

0: Not connected

C00701/32

LS_ParReadWrite_1

: bExecute

0: Not connected

C00701/33

LS_ParReadWrite_1

: bReadWrite

0: Not connected

C00701/34

LA_NCtrl

: bPIDInAct

0: Not connected

C00701/35

LA_NCtrl

: bPIDOff

0: Not connected

Parameter

Info

Lenze setting