C00095

C00097

C00098

C00099

C00100

Parameter | Name:

C00095 | Motor magnetising current

Data type: UNSIGNED_16

Index: 24480

d

= 5FA0

h

After the motor to be used has been selected from the motor catalogue, the suitable value can be entered

automatically. An automatic detection via the motor parameter identification is possible as well.
Display range

(min. value | unit | max. value)

0.00

A

99.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00097 | Rated motor torque

Data type: UNSIGNED_32

Index: 24478

d

= 5F9E

h

Display of the rated motor torque

• The value displayed here is calculated from different parameters, e.g. the maximum current set in

C00022

.

Display range

(min. value | unit | max. value)

0.00

Nm

99.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00098 | Device rated current

Data type: UNSIGNED_16

Index: 24477

d

= 5F9D

h

Display of the rated inverter current which is defined by the integrated power section.
Display range

(min. value | unit | max. value)

0.0

A

999.0

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Parameter | Name:

C00099 | Firmware version

Data type: VISIBLE_STRING

Index: 24476

d

= 5F9C

h

Display of the firmware version of the device as string

Read access  Write access  CINH  PLC-STOP  No transfer  COM  MOT

Character length: 12

Parameter | Name:

C00100 | Firmware version

Data type: UNSIGNED_8

Index: 24475

d

= 5F9B

h

Display of the firmware version of the device, divided into subsections.
Display range

(min. value | unit | max. value)

0

99

Subcodes

Info

C00100/1

Firmware version - main version

C00100/2

Firmware version - subversion

C00100/3

Firmware version - release

C00100/4

Firmware version - build

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1