11
Parameter reference
11.2
Parameter list | C00095
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00095
C00097
C00098
C00099
C00100
Parameter | Name:
C00095 | Motor magnetising current
Data type: UNSIGNED_16
Index: 24480
d
= 5FA0
h
After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically. An automatic detection via the motor parameter identification is possible as well.
Display range
(min. value | unit | max. value)
0.00
A
99.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00097 | Rated motor torque
Data type: UNSIGNED_32
Index: 24478
d
= 5F9E
h
Display of the rated motor torque
• The value displayed here is calculated from different parameters, e.g. the maximum current set in
.
Display range
(min. value | unit | max. value)
0.00
Nm
99.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00098 | Device rated current
Data type: UNSIGNED_16
Index: 24477
d
= 5F9D
h
Display of the rated inverter current which is defined by the integrated power section.
Display range
(min. value | unit | max. value)
0.0
A
999.0
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C00099 | Firmware version
Data type: VISIBLE_STRING
Index: 24476
d
= 5F9C
h
Display of the firmware version of the device as string
Read access Write access CINH PLC-STOP No transfer COM MOT
Character length: 12
Parameter | Name:
C00100 | Firmware version
Data type: UNSIGNED_8
Index: 24475
d
= 5F9B
h
Display of the firmware version of the device, divided into subsections.
Display range
(min. value | unit | max. value)
0
99
Subcodes
Info
C00100/1
Firmware version - main version
C00100/2
Firmware version - subversion
C00100/3
Firmware version - release
C00100/4
Firmware version - build
Read access Write access CINH PLC STOP No transfer COM MOT