7 v/f control (vfcplus + encoder), V/f control (vfcplus + encoder), 5motor control (mctrl) – Lenze 8400 motec User Manual

Page 115

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

115

5

Motor control (MCTRL)

5.7

V/f control (VFCplus + encoder)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.7

V/f control (VFCplus + encoder)

This function extension is available from version 02.00.00!

The V/f characteristic control (VFCplus) described above can be operated with a speed feedback.

This has the following advantages:

• Steady-state accuracy of the speed
• Less parameterisation effort compared to the sensorless vector control (SLVC)
• Improved dynamics compared to V/f characteristic control without feedback or to sensorless

vector control (SLVC).

• Suitability for group drives

The descriptions in chapter "

V/f characteristic control (VFCplus)

" also apply to the V/f

control.

( 96)

Note!

• The speed feedback mandatory for this motor control type can be fed in at the digital

input terminals (DI1/DI2) via an HTL encoder.

• In order that the HTL encoder can be evaluated correctly, the digital input terminals

(DI1/DI2) must be configured as frequency inputs.

Configuring DI1 and DI2 as

frequency inputs

( 185)

• Make sure that the maximum input frequency of 10 kHz is not exceeded when the

motor control with speed feedback is used.

• As the slip is calculated in the feedback V/f operation and injected through the slip

regulator, the slip compensation (

C00021

) is deactivated with V/f control.

Advertising