1 conversion formulae, Conversion formulae, Conversion – Lenze 8400 motec User Manual
Page 484: Formulae, 12 function library
12
Function library
12.15
LS_Convert_3
484
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.15.1
Conversion formulae
The following values are used as factors and divisors for the below-mentioned conversion formulae
depending on the function selected in
:
Function (C01354/3)
Factor
Divisor
0 1 ==> 1 ==> 1
1
1
1 1 Hz ==> % (C11) ==> 1 Hz
1638400
2 * (
[rpm] / 60) * number of pole pairs
(with number of pole pairs =
* 60 /
2 0.1 Hz ==> % (C11) ==> 0.1 Hz
163840
3 0.01 Hz ==> % (C11) ==> 0.01 Hz
16384
4 0.001 Hz ==> % (C11) ==> 0.001 Hz
1638
5 1 rpm ==> % (C11) ==> 1 rpm
16384
[rpm]
6 0.1 rpm ==> % (C11) ==> 0.1 rpm
1638
7 0.01 rpm ==> % (C11) ==> 0.01 rpm
164
8 0.001 rpm ==> % (C11) ==> 0.001 rpm
16
9 1 A ==> % (C22) ==> 1 A
1638400
10 0.1 A ==> % (C22) ==> 0.1 A
163840
11 0.01 A ==> % (C22) ==> 0.01 A
16384
12 0.001 A ==> % (C22) ==> 0.001 A
1638
13 1 Nm ==> % (C57) ==> 1 Nm
16384
[Nm]
14 0.1 Nm ==> % (C57) ==> 0.1 Nm
16384
[Nm] * 10
15 0.01 Nm ==> % (C57) ==> 0.01 Nm
16384
[Nm] * 100
16 0.001 Nm ==> % (C57) ==> 0.001 Nm
1638
17 ACDP ==> CAN ==> ACDP
-
-
18 x C471_1 / C471_2
19 Act position 32bit ==> 16Bit
-
-
General conversion formulae
Out1 [%]
In1 Factor
Divisor
------------------
⋅
=
Out2
In2 [%] Divisor